DC COTACTOR SW822 DC COTACTOR SW822 DC COTACTOR SW822 DC COTACTOR SW822 DC COTACTOR SW822
Next

DC COTACTOR SW822

FOB Price

Get Latest Price

32 / Piece

|

1 Piece Minimum Order

Country:

China

Model No:

SW822

FOB Price:

32 / Piece Get Latest Price

Place of Origin:

-

Price for Minimum Order:

32 per Piece

Minimum Order Quantity:

1 Piece

Packaging Detail:

Export packing

Delivery Time:

4-6DAYS

Supplying Ability:

10000 Piece per Month

Payment Type:

PayPal, Western Union, T/T

Product Group :

Contact Now
Free Member

Contact Person Mr. yang

Changhong Industrial Zone,Liushi Town, Yueqing, Zhejiang

Contact Now

Product Description

DC COTNACTOR SW822
SW822 DC COTNTACTOR

the contactors has been designed for direct current loads, particularly motors as used on electric vehicles such as industrial trucks, airport tractors, and such like.
They have double breaking main contacts with silver alloy contact tips, which are weld resistant, hard wearing and have excellent conductivity.
Compact Size: The contactors are compact in size and are fully serviceable .
 
with a full range of spare parts available.
Installation: Mounting is by means of 5mm tapped holes in the switch frame together with a range of mounting brackets complete with screws and washers.
Operating Coils: Available with 6-240v DC coils, coil connections are by means of 6mm spades of which two are supplied per terminal.
Magnetic Blowouts: Fitting of magnetic blowouts make the polarity sensitive and the positive markings on the top cover of the contactor must be observed. Suffix 'B' denotes the fitting of magnetic blowouts.
Auxiliary Contact: Denoted by 'A', a double circuit normally open, normally closed microswitch auxiliary contact can be fitted, ratings as shown below
 

Contact circuit Voltage and loading current(resistant)24VDC 100A
voltage ( V  DC ): 12VDC,  24VDC, 30VDC,  48VDC,  60VDC,  72VDC,  120VDC.
Contact Resistance 30m©Max.
20±5°C cold state max motion voltage(VDC) Pick-up 70%
Drop-out5%~30%
Machanical life(Min.) 100,000 Ops
Electrical life(Min.) 50,000 Ops
Coil Ratings
Coil rated voltage 12~110 VDC
Max coil current under the rated voltage 0.1A
With 20±5°C cold state starting coil max current 
Specification
Insulation Resistance100M©Min.
Dielectric strength Between Contacts 2000VAC.
Between coil and contacts 1500VAC.
Environment temperature and attitude -40°C~+85°C; 0~20000m
Max relative humidity  98%
The shocking of fixed point 1 Frequency(11Z) 10~200
Acceleration(g) ≤3.5
Shocking    60~100
Acceleration(g) 4
Constant acceleration   8
Operation regulation(Continue)
Installation direction(Random)
imageimage

imageimageimage

DC COTNACTOR SW180
SW180 DC COTNTACTOR

The SW180 series of contactors has been designed for direct current loads, particularly motors as used on electric vehicles such as industrial trucks, airport tractors, and such like.
They have double breaking main contacts with silver alloy contact tips, which are weld resistant, hard wearing and have excellent conductivity.
Compact Size: The contactors are compact in size and are fully serviceable .
 
with a full range of spare parts available.
Installation: Mounting is by means of 5mm tapped holes in the switch frame together with a range of mounting brackets complete with screws and washers.
Operating Coils: Available with 6-240v DC coils, coil connections are by means of 6mm spades of which two are supplied per terminal.
Magnetic Blowouts: Fitting of magnetic blowouts make the polarity sensitive and the positive markings on the top cover of the contactor must be observed. Suffix 'B' denotes the fitting of magnetic blowouts.
Auxiliary Contact: Denoted by 'A', a double circuit normally open, normally closed microswitch auxiliary contact can be fitted, ratings as shown below
 

Contact circuit Voltage and loading current(resistant) 80VDC 200A
Other voltage ( V  DC ): 12VDC,  24VDC, 30DC,  48VDC,  60VDC,  72VDC,  120VDC.
Contact Resistance 30m©Max.
20±5°C cold state max motion voltage(VDC) Pick-up 70%
Drop-out5%~30%
Machanical life(Min.) 100,000 Ops
Electrical life(Min.) 50,000 Ops
Coil Ratings
Coil rated voltage 12~110 VDC
Max coil current under the rated voltage 0.1A
With 20±5°C cold state starting coil max current 
Specification
Insulation Resistance100M©Min.
Dielectric strength Between Contacts 2000VAC.
Between coil and contacts 1500VAC.
Environment temperature and attitude -40°C~+85°C; 0~20000m
Max relative humidity  98%
The shocking of fixed point 1 Frequency(11Z) 10~200
Acceleration(g) ≤3.5
Shocking    60~100
Acceleration(g) 4
Constant acceleration   8
Operation regulation(Continue)
Installation direction(Random)

Country: China
Model No: SW822
FOB Price: 32 / Piece Get Latest Price
Place of Origin: -
Price for Minimum Order: 32 per Piece
Minimum Order Quantity: 1 Piece
Packaging Detail: Export packing
Delivery Time: 4-6DAYS
Supplying Ability: 10000 Piece per Month
Payment Type: PayPal, Western Union, T/T
Product Group : Contactor

Send a direct inquiry to this supplier

To:

Mr. yang < Hongkong North Star Development Co., Limited >

I want to know: